PERBANDINGAN HASIL PEMERIKSAAN LED METODE WESTERGREN ANTARA SAMPEL DENGAN PENGENCERAN DAN SAMPEL TANPA PENGENCERAN

  • Ditaellyana Artha Universitas Indonesia Timur
  • Andi Auliyah Warsyidah Universitas Indonesia Timur
  • Melly Fitriani
Keywords: LED, Metode Westergren

Abstract

This research is motivated by the existence of laboratories that conduct examinations on EDTA blood samples without dilution. The sample taken is the blood of patients who carry out routine examinations in the laboratory of RSUD Syekh Yusuf, Gowa Regency. The purpose of this study is to find out whether there are results of the Westergren method of sedimentary blood examination (LED) for samples with dilution and samples without dilution. This type of research uses laboratory experiments with accidental sampling techniques. The results were processed through a computer using the SPSS program version 22 statistical test methods Paired Sample t Test where t-count (-6.554)> t-table (2.025) and a probability value of 0.000 <0.05 which means Ho is rejected. The conclusion of this study was obtained from the results of the study obtained in the examination of the blood sediment rate (LED) of the Westergren method between the sample with dilution and the sample without dilution (Ho rejected) so that for the LED examination the Westergren method of the sample used is EDTA blood, it is necessary to dilute the sample first.

References

Anonim, 2000. Diktat Hematologi Patologi Klinik, Fakultas Kedokteran Universitas Hasanuddin Makassar.

Bakri, 2015. Penuntun Praktik Klinik Laboratorium Kesehatan. Makassar.

Desmawati, 2013. Sistem Hematologi dan Imunologi. Jakarta: In Media.

Ganda soebrata R. 2010. Penuntun Laboratorium Klinik. Jakarta: Dian Rakyat.
Hardjoeno, H dkk. 2003. Interpretasi Hasil Tes Laboratorium Diagnostik. Makassar : Lembaga Penerbitan Universitas Hasanuddin.
Kiswari, Rukman. 2014. Hematologi dan Transfusi. Jakarta: Erlangga.
Miale, John B. 1962. Laboratory Medicine Hematology. USA: The Mosby Company.
Riswanto, 2009. Laju Endap Darah.
Simmons, 1989. Hematology A Combined Theotitical & Technical Upproach, W.B. Sounders Company.
SolichulHadi, S. 2001. Pemeriksaan Laboratorium Hematologi Rutin Sederhana. Laboratorium Patologi Klinik Fakultas Kedokteran Airlangga Surabaya
Tim Reality, 2009. Kamus Biologi, Srabaya: Reality Publik
Published
2019-12-01
How to Cite
Artha, D., Warsyidah, A., & Fitriani, M. (2019). PERBANDINGAN HASIL PEMERIKSAAN LED METODE WESTERGREN ANTARA SAMPEL DENGAN PENGENCERAN DAN SAMPEL TANPA PENGENCERAN. Jurnal Media Laboran, 9(2), 18-22. Retrieved from https://uit.e-journal.id/MedLAb/article/view/574
Section
Articles